Change history for SSRL - BL11-1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2016-11-14 06:19:32 Status Operational Decommissioned
2016-11-14 06:19:01 Detector: Removed from Service 2015-10-01 2016-10-01
2015-12-01 04:12:07 Detector: Removed from Service 2015-10-01 2011-10-01
2015-10-22 04:48:40 Detector: Removed from Service 2015-10-01
2015-10-22 04:48:08 Detector: Activated for Service 2016-10-01 2011-10-01
2015-10-22 04:47:57 Detector: Model MARmosaic 325 DECTRIS PILATUS 6M
2015-10-22 04:47:52 Detector: Type CCD PIXEL
2015-10-22 04:46:08 Detector: Activated for Service 2011-11-01 2016-10-01
2015-10-22 04:45:22 Detector: Model Dectris PILATUS 6M MARmosaic 325
2015-10-22 04:45:14 Detector: Type PIXEL CCD
2014-09-30 10:40:22 Services High quality data collection, High speed data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution High quality data collection, High speed data collection, Processing, Rapid access, Structure refinement, Structure solution, On-site crystallization facility
2014-09-30 04:10:13 Detector: Activated for Service info currently not available 2011-11-1
2014-09-30 04:09:28 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 Ke and 500 mA Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 keV and 500 mA
2014-09-30 04:08:46 Mirrors Rh coated flat mirror Rh coated focusing mirror
2014-09-30 02:53:43 Lab Facilities COLD ROOM Biochemical lab with cold room; P2 biohazard
2014-09-30 02:30:32 Detector: Details Sample to detector distance: 185 to 650 mm; Maximum vertical offset: 208 mm
2014-09-30 02:30:08 Monochromator Side scattering bent cube-root I-beam single crystal; Asymmetric cut 4.965 degs Side scattering bent cube-root I-beam single crystal; asymmetric cut 4.965 degs
2014-09-30 02:28:39 Services Rapid access High quality data collection, High speed data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution
2014-09-30 02:27:51 Special Capabilities Absorption Edges, Automated Sample Screening, High Throughput Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Resolution, High Throughput, Microspectrophotomer, Shutterless data collection
2014-09-30 02:25:53 Experiments Details MAD experiments are conducted over a limited energy range
2014-09-29 01:57:56 Monochromator Side scattering bent cube-root I-beam single crystal; asymmetric cut 4.965 degs Side scattering bent cube-root I-beam single crystal; Asymmetric cut 4.965 degs
2013-12-20 07:17:05 Energy Range (keV): Max 14.4 15.0
2013-12-20 07:16:57 Energy Range (keV): Min 10.1 10.6
2013-12-20 07:16:48 Wavelength (Å): Min 0.86 0.83
2013-12-20 07:16:38 Flux Coefficient 4.2 2.1
2013-12-20 07:16:24 Spot Size (mm): Width 0.1-0.3 0.1-0.25
2013-12-20 07:16:17 Spot Size (mm): Height 0.1-0.3 0.1-0.2
2013-07-17 07:36:42 Goniometer Details Maximum kappa offset: 30 degrees
2013-07-17 07:36:34 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 Ke and 350 mA Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 Ke and 500 mA
2013-07-17 07:36:13 Spot Size (mm): Width 1.6 0.1-0.3
2013-07-17 07:36:03 Spot Size (mm): Height 0.3 0.1-0.3
2012-03-19 05:15:04 Status operational Operational
2012-03-19 05:13:43 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV and 350mA current Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 Ke and 350 mA
2012-03-19 05:12:58 Services Data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution Rapid access
2012-03-19 04:40:52 Owner/Operator SSRL-SMB-MC; The Scripps Research Institute & and Stanford University SSRL-SMB-MC; The Scripps Research Institute and Stanford University
2012-03-19 04:40:36 Owner/Operator SSRL-SMB-MC; Scripps Research Institute & and Stanford University SSRL-SMB-MC; The Scripps Research Institute & and Stanford University
2012-03-19 04:40:25 Owner/Operator SSRL-SMB-MC; Scripps Research Institute & and Stanford University SSRL-SMB-MC; Scripps Research Institute & and Stanford University
2012-03-19 04:40:09 Owner/Operator SSRL-SMB-MC; Scripps Research Institute (TSRI) & Stanford University SSRL-SMB-MC; Scripps Research Institute & and Stanford University
2012-03-19 04:39:54 Owner/Operator SSRL-SMB-MC; Scripps Research Institute (TSRI) & Stanford University and SSRL-SMB-MC; Scripps Research Institute (TSRI) & Stanford University
2012-03-19 04:39:45 Owner/Operator Scripps Research Institute (TSRI), Stanford University and SSRL-SMB-MC SSRL-SMB-MC; Scripps Research Institute (TSRI) & Stanford University and
2011-12-09 10:07:33 Detector: Details Sample to detector distance: 106 to 650 mm; Maximum vertical offset: 208 mm Sample to detector distance: 185 to 650 mm; Maximum vertical offset: 208 mm
2011-11-28 06:06:22 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV and 200mA current Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV and 350mA current
2011-11-28 06:04:28 Detector: Type CCD PIXEL
2011-11-28 06:03:05 Detector: Model MARmosaic 325 Dectris PILATUS 6M
2011-11-28 05:24:23 Spot Size (mm): Height 1.6 0.3
2011-11-28 05:24:08 Detector: Details Sample to detector distance: 106 to 650 mm; Maximum vertical offset: 175 mm Sample to detector distance: 106 to 650 mm; Maximum vertical offset: 208 mm
2011-11-28 05:23:38 Detector: Details Sample to detector distance: 90 to 650 mm; Maximum vertical offset: 175 mm Sample to detector distance: 106 to 650 mm; Maximum vertical offset: 175 mm
2011-11-28 05:22:58 Energy Range (keV): Max 15.2 14.4
2011-11-28 05:22:52 Wavelength (Å): Min 0.82 0.86
2011-11-28 05:22:40 Spot Size (mm): Width 0.4 1.6
2011-11-28 05:22:09 Flux Coefficient 5.7 4.2
2009-11-18 02:41:07 Cryo Capability Details 100K to room temperature
2009-11-18 02:40:50 Lab Facilities Beamline cold room Biochemical lab with cold room COLD ROOM
2009-11-18 02:38:07 Detector: Details Sample to detector distance: 90 to 650 mm; Maximum vertical offset: 175 mm
2009-11-18 02:37:00 Robotics: More Info http://smb.slac.stanford.edu/users_guide/
2009-11-18 02:36:11 Goniometer Details Maximum kappa offset: 30 degrees
2009-11-18 02:35:11 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV and 200mA current
2009-11-18 02:34:54 Flux Coefficient 7.0 5.7
2009-11-18 02:33:10 Spot Size (mm): Width 0.3 0.4
2009-11-18 02:33:04 Spot Size (mm): Height 1.2 1.6
2009-11-18 02:31:38 Source Type bending magnet INSERTION DEVICE
2009-11-18 02:31:03 Services Data collection Data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution
2009-11-18 02:29:53 Special Capabilities Automated Sample Screening Absorption Edges, Automated Sample Screening, High Throughput
2009-11-18 02:18:57 Experiments Details MAD experiments are conducted over a limited energy range MAD experiments are conducted over a limited energy range
2009-11-18 02:18:51 Experiments MAD, SAD MAD, SAD, MONOCHROMATIC
2009-11-18 02:18:42 Experiments MAD, SAD MAD, SAD
2009-08-04 02:09:39 Services Automated crystal screening Data collection
2009-08-04 02:09:26 Special Capabilities Details Full remote access
2009-08-04 02:09:16 Special Capabilities null Automated Sample Screening
2009-08-04 02:09:09 Special Capabilities Details