Change history for SSRL - BL9-1

Print

Date/time of ChangeAttributePrevious ValueUpdated Value
2014-09-30 10:38:28 Services High quality data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution High quality data collection, Processing, Rapid access, Structure refinement, Structure solution, On-site crystallization facility
2014-09-30 08:11:17 Energy Range (keV): Min 12.55 12.6
2014-09-30 08:11:10 Wavelength (Å): Max 0.99 0.98
2014-09-30 04:30:40 Services High quality data collection, On-site cyrstallization facility, Rapid access, Structure refinement, Structure solution High quality data collection, On-site cyrstallization facility, Processing, Rapid access, Structure refinement, Structure solution
2014-09-30 04:29:49 Special Capabilities Absorption Edges, Automated Sample Screening, High Resolution Absorption Edges, Automatic Crystal Alignment, Automated Sample Screening, High Resolution, High Throughput
2014-09-30 03:48:23 %Time Available (general use) 100 0
2014-09-30 02:53:09 Lab Facilities Biochemical lab with cold room Biochemical lab with cold room; P2 biohazard
2014-09-30 02:33:29 Lab Facilities Biochemical lab with cold room Biochemical lab with cold room
2014-09-30 02:32:45 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 KeV; 350 mA Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 keV and 500 mA
2014-09-30 02:32:01 Special Capabilities Details Fukk remote access Full remote access
2014-09-30 02:10:17 Cryo Capability Details 100K - room temperature 100K - room temperature
2014-09-30 02:10:06 Cryo Capability Details 100K - room temperature
2014-09-30 02:09:30 Robotics: More Info See http://smb.slac.stanford.edu/users_guide/
2014-09-30 02:08:45 Mirrors Flat mirror, Rh coated Rh coated focusing mirror
2014-09-30 02:08:26 Monochromator Side-scattering cuberoot I-beam bent single crystal; Asymetric cut 12.2 degs. Side-scattering cuberoot I-beam bent single crystal; asymetric cut 12.2 degs.
2014-09-30 02:08:09 Spot Size (mm): Width 0.23 0.1-0.25
2014-09-30 02:07:58 Spot Size (mm): Height 2.20 0.1-0.2
2014-09-30 02:07:39 Source Type bending magnet INSERTION DEVICE
2014-09-30 02:07:26 Services Rapid access High quality data collection, On-site cyrstallization facility, Rapid access, Structure refinement, Structure solution
2014-09-30 02:06:55 Special Capabilities Details Fukk remote access
2014-09-30 02:06:43 Special Capabilities Automated Sample Screening Absorption Edges, Automated Sample Screening, High Resolution
2014-09-30 02:06:09 Status Details Flat mirror is being replaced The focusing mirror is being replaced
2014-09-29 02:04:00 Status Details Staff Development Flat mirror is being replaced
2014-09-29 01:56:54 Detector: Removed from Service 2010-03-01
2014-09-29 01:56:31 Detector: Activated for Service 2010-11-11 2009-11-02
2014-09-29 01:55:58 Detector: Model ADSC Quantum 1 DECTRIS PILATUS 6M
2014-09-29 01:55:54 Detector: Type CCD PIXEL
2014-09-29 01:55:20 Detector: Activated for Service 2009-11-02 2010-11-11
2014-09-29 01:54:46 Detector: Activated for Service 2009-11-02 2009-11-02
2014-09-29 01:54:00 Detector: Model DECTRIS PILATUS 6M ADSC Quantum 1
2014-09-29 01:53:52 Detector: Type PIXEL CCD
2014-09-29 01:53:36 Monochromator Side-scattering cuberoot I-beam bent single crystal; asymetric cut 12.2 degs. Side-scattering cuberoot I-beam bent single crystal; Asymetric cut 12.2 degs.
2014-09-29 01:53:01 Status Operational Undergoing upgrade
2012-03-19 05:10:32 Flux Details Flux measured through a 0.2 x 0.2 mm2 aperture at 12658 eV Flux measured through a 0.2 x 0.2 mm2 aperture at 12.6 KeV; 350 mA
2012-03-19 05:09:59 Flux Coefficient 7.2 9
2012-03-19 05:09:29 Spot Size (mm): Height 2.2 2.20
2012-03-19 05:09:12 Services Data collection Rapid access
2012-03-19 05:08:49 Experiments SAD, MAD MAD, SAD, MONOCHROMATIC
2012-03-19 05:08:31 Status operational Operational
2012-03-19 05:08:27 Status Details Staff Development
2010-03-26 05:26:17 Detector: Activated for Service info currently not available 2010-03-01
2009-08-04 02:06:32 Services Data collection
2009-08-04 02:06:26 Special Capabilities Absorption Edges Automated Sample Screening